0x00 |
No Error |
Command
complete successfully. |
0x10 |
Test
aborted by user. |
The
current test was canceled by user and cannot be completed. Rerun the test to
conclusion |
0x20 |
Selected
device not present. |
The
selected device could not be found on the selected port. Check cabling and
HDD connectors. If the drive is not seen by the BIOS or is not spinning |
0x21 |
ATA
Master device not present. |
An
attempt was made to test an ATA Slave device, but an ATA Master cannot be
detected. A Master must be present to test a Slave. Check cabling and HDD
connectors. |
0x22 |
Device
Protected, |
Selected
device is protected by a password. The drive is write and read protected and
cannot be tested |
0x23 |
Format
Degraded. |
A
SCSI low-level format was interrupted. |
0x30 |
Out
of memory. |
There’s
not enough memory to execute this program. |
0x31 |
Wrong
parameter. |
There
is a wrong or unknown parameter. |
0x33 |
Function cannot be executed on this device. |
0x40 |
System
interrupts the current operation. |
The
System has interrupted the current operation, and the function was aborted.
Please exit the program and check if any Power Saving Modes or Cache Programs
(like SMARTDRV.EXE) are active. Disable those features and start this program
again. |
0x41 |
Bad
cable. |
A
data miss compare was detected during the cable test. |
0x42 |
Drive
temperature problem. |
The
drive has exceeded the drive temperature limit |
0x43 |
Pending
SCSI request. |
The
ASPI Device driver could not complete the SCSI request block. Check the SCSI
configuration (cabling, termination, Ids etc.). |
0x44 |
System
Vibration |
The
level of vibration that the drive is experiencing is excessive, check the
mounting of the drive in the system and ensure it is rigidly mounted. If
possible try mounting the drive in a different position. |
0x45 |
Low System Performance |
0x70 |
Corrupted
Sector. |
A
general hard disk drive problem was detected. You can run the "Erase
Disk" utility. If a subsequent test fails again, the drive is defective
and should be replaced. |
0x71 |
Device
not ready. |
The
selected drive is not ready for operation. Check cabling and HDD connectors. |
0x72 |
Device
S.M.A.R.T. Error. |
The
Self-Monitoring, Analysis and Reporting Technology (S.M.A.R.T.) has detected
a drive problem. The drive may fail soon and should be replaced as soon as
possible. |
0x73 |
Device
damaged by shock. |
This
device was damaged by an excessive shock |
0x74 |
S.M.A.R.T
Self-test failed |
An
error was detected during S.M.A.R.T. self-test. You can run the "Erase
Disk" utility of DFT. If a subsequent test fails again, the drive is
defective and should be replaced |
0x75 |